Introduction to polyurethane hydrocyclones widely used in desander and desilter.
The material of the desilter hydrocyclones is polyurethane, and the material of the sand settling port is polyurethane + KM wear-resistant coating. The desilter hydrocyclones is equipped with three specifications of underflow ports: Φ14, Φ18, and Φ22. The appropriate specification should be selected according to different mud conditions. The feed pressure should be controlled between 0.08-0.30 MPa.
The material of the desander hydrocyclones is a steel shell lined with rubber, and the material of the sand settling port is high-alumina ceramic. The desander hydrocyclones is equipped with three specifications of underflow ports: Φ70, Φ80, and Φ90. The appropriate specification should be selected according to different mud conditions. The feed pressure should be controlled between 0.03-0.40 MPa.
Storage precautions for polyurethane hydrocyclones:
The rubber lining components of the cyclone should not be exposed to direct sunlight for a long time during storage because strong ultraviolet rays can cause aging of these materials. The equipment should be stored indoors as much as possible. If stored outdoors, it should always be covered with tarps or other protective layers.
The hydrocyclones shall be placed under a safe environment, so as to avoid any damage on cyclone caused by fallen object or other heavy stuff.
The hydrocyclones shall be kept away from any corrosive liquid or smog.
The equipment should be kept away from high temperatures, direct flame, and welding.